Description: Feature: Made of high quality ABS, it is corrosion resistant and is the perfect choice for the home and power industry. Completely insulated, with no exposed metal and conductive parts, safer to use. Compact structure, small in size, lightweight, safe and easy to carry. This product can be used repeatedly and repeatedly for life and service life. It is ideal for testing power lines, circuit breakers, wall sockets, junction boxes, fuses, and more. Specifications: Condition: Brand New Material: ABS Color: Black Working environment: 0~40°C Relative humidity: less than 85% Voltage detection range: 48V~1000V AC Frequency range: 50Hz/60Hz Security category: CAT 3 level 1000V Power: 2 * AAA Batteries (Battery not included) Package list: 1 * Test Pencil (Battery not included) 1 * Instruction Manual Instructions: Turn the tester on/off: Turn on the tester: press the power on key, tester self-test, flashlight, induced voltage signal indicator, signal strength indicator (high, medium, low), the button indicator flashes once, and the power indicator is always on. Turn off the tester: With the tester turned on, press the power switch and the power indicator is off. Turn on/off the flashlight: Turn on the flashlight: With the tester turned on, press the flashlight to turn on the key and turn on the flashlight. Turn off the flashlight: With the flashlight turned on, press the flashlight to turn the key off and turn off the flashlight. If the flashlight is not turned off, it will automatically go out after about 5 minutes. AC voltage detection: Insert the probe of the tester into the power socket or close to the live wire. When the tester detects the AC voltage signal, the induced voltage signal indicator flashes. The tester lights the corresponding signal strength indicator according to the detected signal strength (high, Medium and low), while the beeper emits alarm sounds of different frequencies. When the AC voltage signal is sensed, the L signal strength indicator (low) flashes; when a higher AC voltage signal is sensed, the M signal strength indicator (middle) is bright; when the highest AC voltage signal is sensed, the H signal The indicator (high) 3 lights are shining. Zero line / fire line identification: The two wires to be tested are separated as much as possible, and then the probes of the tester are respectively placed close to the wires. If the socket is the socket, the probe is inserted into the jack, and the tester detects that the strong signal is a fire wire, and the sensing signal is weak. Or no signal is the zero line. AC voltage detection range selection: The tester starts the immersive AC voltage detection range: about 48~1000V. Tap the AC voltage detection range to switch the key (S), the detection range indicator lights up, and the tester can detect the voltage range from about 12 to 1000V. Press the AC voltage detection range switch key (S) again, the detection range indicator is off, and the tester can detect the voltage range of about 48-1000V. Automatic shutdown function: When the tester is not operating for about 5 minutes and no voltage signal is detected, the tester will automatically shut down. Battery undervoltage indication: When the battery voltage is lower than about 2.6V, the power indicator flashes 3 times, and the buzzer will sound automatically to shut down. Please replace the battery in. Panel description: Probe (sensor head); Flashlight; Induced voltage signal indicator; Signal strength indicator: high (H), medium (M), low (L); Power switch key with power indicator light; Flashlight switch key; The AC voltage detection range is switched on and off (S); With detection range indicator; Battery cover. Battery replacement: Rotate the battery cover; Remove the old battery; Insert a new battery as indicated by the positive and negative battery. WARNING: To avoid electric shock, do not use the battery cover until it is properly seated. Note: To avoid possible electric shock or personal injury: Please use the tester strictly according to this manual, otherwise the function provided by the tester may be affected. Do not use if the power indicator is not lit. Before use, test on a known powered power supply to ensure that the product is in good working order. When using this tester, there may be voltages even if there is no sound or light meal. The tester only indicates the effective voltage when an AC voltage is generated to generate a sufficient electrostatic field. If the electric field strength is low, the tester may not detect it. The tester may be affected by the following factors, including but not limited to: Shielded wires/cables, thickness and type of insulation, distance from high voltage sources, complete insulation, differences in socket design, etc. Do not use if the tester is damaged or the tester is not working properly. Before use, check the probe for cracks or breaks. If you suspect any problems, please send the tester in. Do not apply more than the rated voltage marked on the tester. Test the AC voltage 36V, be careful to avoid the of electric shock. Use appropriate protective equipment in accordance with local or national authority regulations.
Price: 10.2 USD
Location: Cranbury, NJ, 08512
End Time: 2024-12-30T01:44:24.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Unbranded