Description: NEW Patient Monitor CMS6000+Etco2 IntroductionThe monitor has abundant monitoring functions and is used for monitoring of adult, pediatric and neonate. User may select different parameter configurations according to different requirements. It displays real-time data and waveform by 8'' TFT color LCD, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. 48mm thermal printer is optional. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system.This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving.FunctionsStandard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis2)RESP Respiration rate(RR) Respiration waveform3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)5)TEMP T1, T2, TDIt has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.Features1)8'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.3)All-round monitor for adult, pediatric and neonate.4)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.5)Waveform, parameter color and location can be set optionally.6)Operation mode: keys and buttons.7)Display up to 8-channel waveform on one screen.8)Display 7-lead ECG waveform on one screen, and with ECG step function.9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.10)HRV analysis function.11)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.12)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.13)Drug concentration calculation and titration table functions.14)Print trend table data with one-key.15)Connect to Central Monitoring System by WiFi or wired mode.16)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.17)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).Performance▲ECGLead mode: 3-lead or 5-leadLead selection: I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, 2-channel3-lead, 1-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan speed: 12.5mm/s, 25 mm/s, 50 mm/sHR:Measurement and alarm range: 15~350bpmAccuracy: ±1% or ±1bpm, whichever is greaterAlarm accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement and alarm range: -2.0mV~+2.0mVAccuracy: -0.8mV~+0.8mV ±0.04mv or ±10%, whichever is greaterOther range: unspecifiedArrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCPacemaker: yesRESPIRATIONMethod: R-F(RA-LL) ImpedanceRespiration rate:Measurement and alarm range: 0~150rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s▲NIBPMethod: OscillometryMode: Manual/AUTO/STATMeasurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period in STAT mode: 5 minutesMeasurement and alarm range: 10 ~ 270 mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement accuracy:Maximal mean deviation: ±5 mmHgMaximal standard deviation: 8mmHgOver-pressure protection:Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg▲SpO2Measurement and alarm range: 0 ~ 100%Resolution: 1%Measurement accuracy: 70%~100%: ±2%;0%~69%: unspecifiedPRMeasurement and alarm range: 30 ~ 250 bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is greaterTEMPChannel: dual-channelMeasurement and alarm range: 0 ~ 50℃Resolution: 0.1 ℃Accuracy: ±0.1 ℃▲EtCO2Method: Sidestream or MainstreamMeasurement range for CO2: 0 ~ 150mmHgResolution for CO2: 0.1 mm Hg: 0 ~ 69 mm Hg 0.25 mm Hg: 70 ~ 150 mm HgAccuracy for CO2: 0 ~ 40 mm Hg: ±2 mm Hg 41 ~ 70 mm Hg: ±5% 71 ~ 100 mm Hg: ±8% 101 ~ 150 mm Hg: ±10%AwRR range: 2~150 rpmAwRR accuracy: ±1 rpmApnea alarm: yesIBPChannel: dual-channelLabel: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measurement and alarm range: -10~300 mm HgResolution: 1 mmHgAccuracy: ±2% or 1mm Hg, whichever is greaterPower supply:100-240V~, 50/60HzSafety classification: Class I, type CF defibrillation-proof applied partAccessoriesAdult fingertip SpO2 probe (5-pin)Adult NIBP cuffNIBP extension tubeECG lead cableECG electrodeTemperature probePower cordUser ManualPhysical characteristicDimension: 235 mm(L) × 141 mm(W) × 222 mm(H)Weight: 2.5 Kg
Price: 658 USD
Location: Beijing
End Time: 2023-10-01T03:12:55.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: Contec
Screen Dimensions: 8'' color TFT LCD
Technology: Digital
Model: CMS6000
UPC: Does not apply
MPN: Does Not Apply
Features: Battery Operated
Bundle Listing: Yes
Country/Region of Manufacture: China
Monitor Parameters: Blood Pressure, Blood Pressure - NIBP, O2 - SpO2
Intended Use/Discipline: Cardiology, Emergency Medicine, Medical Laboratory